testo 335 is the new generation flue gas analyser, specially tailored to industrial applications' requirements. testo 335 can be used for all emission monitoring applications by the operators of industrial furnaces such as processing and power plants, by service technicians for burner/furnace manufacturers, for plant construction as well as for stationary motors. Even spot measurements for up to 2 hours are possible.
Feature:
- max. 3 measurement cells
- Two toxic measurement cells, freely selectable
- High-performance automatically controlled membrane pump
- Logger function
- Parallel ΔP and m/s for flue gas measurement
- 2 measurement range extensions (standard: single dilution with factor 5, option:dilution for all sensors with factor 2)
General informations:
|
Controlled diaphragm pump |
Hose length max. 7.8m (corresponds to two probe hose extensions) Max positive pressure/flue gas +50mbar Max negative pressure/flue gas -200mbar |
| User-defineable fuels | 10 user-defineable fuels incl. test gas as fuel |
| Oper. temp. |
-5 to +50°C |
Accessories
Technical Data
|
|
|
||||
|
O2 meas. |
|
||||
|
CO meas. (H2 compensated) |
|
||||
|
COlow meas. (H2 compensated) |
|
||||
| NO meas. |
|
||||
|
NOlow meas. |
|
||||
|
NO2 meas. |
|
||||
|
SO2 meas. |
|
||||
|
Temp. meas. probe type |
|
||||
|
Draught meas. |
|
||||
|
Differential pressure meas. |
|
||||
|
Absolute pressure meas. |
|
||||
|
Derived parameters
Efficiency Flue gas loss Flue gas dewpoint |
|
||||
|
CO2 meas. (calculation from O2) Response time t90=<40s |
|
PDF's
![]() |
|
|
| Click here for the pdf brochure | Click here for more informations | |
Measure. range extension
|
Single dilution factor 5 (standard) |
||
|
CO meas. (H2 compensated) |
Meas. range Accuracy Resolution |
700ppm to 50000ppm ±10% of mv (additional error) 1 ppm |
|
COlow meas. (H2 compensated) |
Meas. range Accuracy Resolution |
500ppm to 2500ppm ±10% of mv (additional error) 0.1 ppm |
|
NO2 meas. |
Meas. range Accuracy Resolution |
200ppm to 2500ppm ±10% of mv (additional error) 0.1 ppm |
|
SO2 meas. |
Meas. range Accuracy Resolution |
500ppm to 25000ppm ±10% of mv (additional error) 1 ppm |
|
Dilution of all sensors, Factor 2 (option 0440 3350) |
||
|
O2 meas. |
If meas. range extension is activated on all sensors: Accuracy: ±1Vol.% additional error (0 to 4.99Vol.%) ±0.5Vol.% additional error (5 to 25Vol.%) |
|
|
CO meas. (H2 compensated) |
Meas. range Accuracy Resolution |
700ppm to 20000ppm ±10% of mv (additional error) 1 ppm |
|
COlow meas. (H2 compensated) |
Meas. range Accuracy Resolution |
500ppm to 1000ppm ±10% of mv (additional error) 0.1 ppm |
|
NO meas. |
Meas. range Accuracy Resolution |
500ppm to 6000ppm ±10% of mv (additional error) 1 ppm |
|
NOlow meas. |
Meas. range Accuracy Resolution |
300ppm to 600ppm ±10% of mv (additional error) 0.1 ppm |
|
NO2 meas. |
Meas. range Accuracy Resolution |
200ppm to 1000ppm ±10% of mv (additional error) 0.1 ppm |
|
SO2 meas. |
Meas. range Accuracy Resolution |
500ppm to 1000ppm ±10% of mv (additional error) 1 ppm |